Overview The purpose of this file is to allow for the Manual installation of Windows NT4.0 Workstation or Server with the SMC PCI Adapters. Supported Adapters: SMC1211TX 10/100 This software distribution has unattended files and sample scripts for WindowsNT 4.0 Workstation and Server. The sample Unattended script is: WindowsNT 4.0 Workstation/Server = /UNATTEND.TXT The WindowsNT 4.0 Workstation/Server script has been designed to install NT with the following options: (your site could have different requirements) · FileSystem ===> FAT · Workgroup ===> WORKGROUP, ie not into a DOMAIN · NT root directory ===> \WINNT40 · Networking protocols used ===> NetBEUI, IPX Note : For best results with multiple machines it is recommended that you use this file in conjunction with an UDF file to customize options such "ComputerName" and "FullName". Installation Steps: 1) Extract the Compress file. 2) Create a new Subdirectory structure on your Network Installation Server within the WindowsNT distribution share point. The new directory structure is shown in the Example below: EXAMPLE: F:\WINNT\i386 - Distribution Share Point on Server ADD: \$OEM$\NET\SMC - Directory Structure The directory structure once completed should look like this: EXAMPLE: F:\WINNT\I386\$OEM$\NET\SMC 3) Copy the SMC Drivers into the new SMC subdirectory: EXAMPLE: UNATTEND.TXT SMC1211.SYS OEMSETUP.INF 4) If you are using your own Unattend.txt file please take note of the sections below. Please add these sections to your existing script file: [Unattended] OemPreinstall = yes [Network] InstallAdapters = SelectedAdaptersSection [SelectedAdaptersSection] SMC1211 = OEMAdapterParamSection, \$OEM$\NET\SMC [OEMAdapterParamSection] Command line execution Start NT installation with the following command line {source}\winnt.exe /B /S:{source} /U:{source}\$OEM$\NET\SMC\UNATTEND.TXT. Where {source} is the source drive and source directory on the distribution software server. In this example the share point directory is called F:\WINNT\I386. This Example assumes that it is executed from within the I386 Directory. EXAMPLE: WINNT /B /S:F:\WINNT\I386 /U:F:\WINNT\I386\$OEM$\NET\SMC\UNATTEND.TXT For further information on using attended installation with Microsoft Windows NT Workstation or Server see Windows NT Resource Kit or contact Microsoft Corporation. SMC Networks, Inc. This commercial computer software and documentation is provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the Government is subject to restrictions set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c) (1) and (2) of the Commercial Computer Software -- Restricted Rights clause at FAR 52.227-19, or Alternate III of the Rights in Data - General clause at FAR 52.227-14, as applicable. The manufacturer / subcontractor is SMC Networks, Inc. 6 Hughes, Irvine CA. SMC and Standard Microsystems are registered trademarks; and EtherPower, EtherPower^2, EtherPower 10/100, EZStart, and SuperDisk are trademarks of Standard Microsystems Corporation. Other product and company names are registered trademarks or trademarks of their respective holders.